200 BEDS HOSPITAL INCENERATOR TECHNICAL INFORMATIONS

1) Policy – Waste disposal management shall be taken special note to prevent hospital infection. – Infections wastes shall be managed, stored strictly and burned by a incinerator located at hospital site.   2) Waste Disposal Plan a) Classification – Medical wastes in hospital are classified as follows;   Infections Waste Specially-controlled waste Organ, needle, etc. Industrial waste … Read more

SOLID WASTE INCINERATOR Feeding Capacity 200 to 220 Kg

Burn Rate * 60 Kg / hr Ingredients to be burned Cotton, Rubber, PVC Sheets, PE Gloves, Oil, Plastic Bottles, Paper etc. Chambers * Dual Chamber. 1: Primary Controlled Air 2: Secondary Excess Air Temperature Monitoring Required Temperature Control to Primary & Secondary Chambers Required System Status & Alarms Required for all necessary parameters. Fittings & Accessories Complete Package is required ( Including Nozzles & Flanges etc.) Installation Requirements. As low as possible . Almost Plug & Play type. Dimensional Sketch, Operation & Installation Manuals. Required Off – Gas System Required Heat Insulation Required for indoor installation Delivery Karachi Sea Port – Pakistan The details of Components of incinerator is as follows: Component Name     Features              Range.        Primary Chamber Temperature Required* 800 – 1000 deg C. Heating Source Natural Gas      Secondary Chamber Temperature * 1100 – 1300 deg. C Heating Source Natural Gas + Propane or Fuel Oil as an additional source Off – Gas Residence Time  2 Seconds.   Refractory Material Material * Alumina ( 56 – 80 % Pure ) Lining * SS 316L Life Span * 10 – 15 years. Rating Temperature 1600 – 1800 deg. C Media Slightly acidic             Insulation Material … Read more

Fw: waste disposal range treatment capacity: 35 kg incinerator

 Suitable models for required waste disposal range.  Combustion efficiently per hour based on 08hrs operation and its fuel category  installation method C Mobile type/ possibility of structured inside container / structured in permanent base   Fuel consumption details consisting electricity  Capacity: 20KG/Hr, Temp Range: 600 Deg. C C 1100 Deg. C  Fuel Supply: Natural Gas/Diesel Dual Combustion Chamber Complete Scrubbing System (Dual  Resultant Gas Washer), Dual Blower, Chimney Height: 8m Electric Supply: 220/240Volt, Single Phase  Waste treatment capacity: 35 kg / h The combustion chamber is thick steel plate (3 to 10 mm ) with reinforcements, specially built . Front loading with watertight door mounted on hinges, locking screw wheel , flexible gasket and an insulating refractory lined  . An internal lining of refractory concrete containing 42% of H2 03 (alumina ) and 100 mm thick walls. fibrous insulation panels made ??of calcium silicate with a thickness of 75mm . Automatic Burner ( diesel or gas must be specified in the order ) with flames diving in one piece monoblock with an electronic  ignition system , permanent ventilation control valve and isolation valve. combustion floor made ??in carborundum , preventing binding of glass and slag. Equipped with two (02) chambers Fuel: Gas or butane gas Power supply: 220 V 50 Hz single-phase Capacity 100 Kg (0.18 m3) Electric starter ・       The room dimensions are 6.64 m width x 6.61 m length x 6.03 m height at lowest point/per one incinerator. Are these  dimensions sufficient for complete one medical incinerator 150 kg/hours (1.5ton/day). ・       Please, provide complete data about chemical consumption required for waste incineration, gas emission treatment  ,liquid waste and generated soiled wastes handling and/or, treatment . ・       Please, confirm that the exhaust gases are treated by alkaline scrubbing (wet or dry).

Solid waste incinerator placed in a container

Solid waste incinerator, productivity 100kg/h placed in a container.  Dimensions: 2,45×12,2m and 2,9m in height.   Operates natural gas with the pressure of 0.005 MPa and consumption of 0,21-0,23 m3 per kg of waste. Installed power C 55 kW. Total 3 units. Fuel capacity:200l or more Incinerator has a temperature monitoring system in place Wet scrubber capable of removing sulpur dioxide in the fumes Water capacity of 2000l or more Incinerator temeprature above 950 degree celsius Incinerator used a dual chamber system for incinerator Capacity per hour at least 25kg 1. A combustion chamber : a. watertight door for manual loading of waste. b . A burner start is limited to inflammation of waste . 2. A camera post-combustion gases : a. burner combustion , low power . b . An injection device air for total recombustion of the gases . c . An input device cooling air of the combustion gases. d . A smoke evacuation duct .   3. A control panel ensuring complete combustion cycle .   The incinerator meets as indicated on waste incineration . They will not burn plastics, packaging except that the amount so small that gases need not receive any treatment, secondary combustion chamber to 1100C handles everything ..   Water waste incinerator, productivity up to 3m3/h and placed in a modular building. Dimensions: 8,2×5,9m and 5m in height.  Operates natural gas with the pressure of 0,016 MPa and consumption of 0,35m3 / kg of drainage. Installed power C 35 kW. Total 1 unit.

Hot Medical Waste Disposing Machine

Type Pyrolytic:- Hot Medical Waste Disposing Machine Operation Condition 8-16 Hr /day Controls Built in data recording Incinerator  /Primary Combustion Chamber Type: continuous loading  Capacity/Burn rate per hour: 250 -300kg/hr  Temperature:  900-1200 oC   Material: External- 3 layers  Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or gas and to thermal shock Secondary  Combustion  Chamber Type: horizontal/vertical Temperature: 1200-1400 oC Residence time of gases : >2 seconds Material External- Low thermal mass insulation 14-30 oC  Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium nettle lining, resistant to corrosive waste or gas and to thermal shock. Ash Handling System Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash. Flue gas treatment   system         Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc.  Auxiliary device: Fuel cut off device Waste  feeding mechanism Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800L at a time                                                                                                                                       Chimney (Stack) Type: Vertical type height: 7-10 meters  Material: Fireproof cast, stainless steel  Wet scrubbing system Vertical sprat tower with baffles or packing inside Gas emission Reduction of Pollutant gas SO2, HCL, HF and line particulate OUTPUT ASH -Max <5% of original waste size GAS- SMOKELESS,ODORLESS Emission standard WHO/ European Test report for emission testing Must be provided Product Data sheet/ Catalogue Must be attached to the ITB Additional Requirement -Local agent or branch in Ethiopia -Training for users as well as for EPHI maintenance staff  on preventive maintenance … Read more

Containerized Mobile Incinerators

○ Containerized Mobile Incinerator(CA Model) HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to the construction of on-site facilities … Read more

Containerized Mobile Incinerator

○ Containerized Mobile Incinerator(CA Model) HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to the construction of on-site facilities … Read more

HICLOVER Waste Incinerator

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, … Read more

what’s Incinerators

Incinerator, incineration equipment to burn material you want to burn. most of time, Incinerator for waste burning, including solid waste, liquid waste and gas waste. the Incinerator fuel including oil, gas, coal, wood, etc. the fuel function for start burn, keep waste burn or only keep burn itself to get high temperature. Incinerator request 1/2/3/more … Read more

medical waste and general waste Incinerate

Incinerate: medical waste and general waste Capacity to burn waste: 400-500kg/hr Fuel: Diesel Fuel Consumption: 10 liters/hr maximum Incineration temperature: 950-1300 degrees centigrade Casing: thick (min 5mm) stainless steel casing and fully insulated to withstand sea humidity Voltage 220/240v or 380/415V Frequency 50Hz Feeding: Automatic Ash/leftovers removal: Automatic Flue gas filtration system: Yes Quantity: Four (4)  Type: Pyrolytic  Use: For drugs  With Chassis to be Mounted in truck/lorry  May have a primary and secondary combustion chamber  Must have a dilution chamber Capacity: 100 Kgs per hour Power Source: Diesel or Natural Gas or Liquified Natural Gas